It can automatically calculate the thickness of the coating.
1. The thickness gauge is used to measure the thickness of metal plating and coated plates, such as paint/enamel/chromium on steel, paint and anodized coating on aluminum/copper.
2. The measuring range is 0-2000um.
3. The instrument uses a built-in precision probe, and uses the principle of electromagnetic induction and eddy current effect to automatically detect the properties of the substrate.
4. The meter is designed to measure coating and paint thickness non-destructively.
5 It is essential for the surface treatment of materials. It is widely used in manufacturing, metal processing, chemical, and
commodity inspection fields. It can also be used in laboratories,workshops and outdoors.
Probe: F probe, N probe
Magnetic induction: measuring principle (F), eddy current effect (N)
Measuring range: 0-2000um
Accuracy:±(3% + 1um)
Resolution: 0um-99.9um(0.1um) 100um-999um(1um)>1000um(0.01mm)
Zero adjustment: support
Statistics: average, minimum,maximum, quantity
unit:. Mm mil
Minimum convex arc: 5mm
Minimum concave arc: 25mm
Minimum measuring area: 20mm in diameter
Minimum substrate thickness: 0.2mm 0.05mm
Maximum measurement speed: 2 readings per second
Power supply: 2 x 1.5V AAA batteries (not included).
Working environment: temperature 0-50℃, 20-90%rh (non-condensing)
Maintenance environment: temperature: -10-60℃,20-90%rh (non-condensing)
Size/weight/material: 113mmX53mmX2 4mm/80g/ABS